Complete Guide

How to reconstitute a research peptide.

The full step-by-step walkthrough: supplies, technique, the concentration math, reading a U-100 syringe, storage, and the mistakes that ruin a vial. Research use only.

Step 1 of 6 Compound Live

What are you reconstituting?

/
Pick the compound you are reconstituting. Not on the list? Choose Custom compound at the bottom and enter your own vial size.
Compoundselected

How many milligrams are in your vial?

Look at your vial label for the total mg of lyophilized (freeze dried) powder. This is the whole amount in the vial, not a portion. Common sizes for this compound are shown above.
▶ How to read your vial
Compoundvial

How much bacteriostatic water are you adding?

That makes a concentration of2.5mg/mL
Bacteriostatic water is the sterile liquid you mix into the vial. More water = lower concentration = a bigger, easier to measure draw. The range above is what researchers commonly use for this compound. Anything in it works, it just changes how concentrated the vial is.
▶ How to add BAC water
Compoundamount

How much do you want per aliquot?

The research quantity you want in each measured portion, called an aliquot. Switch between mcg (micrograms) and mg (milligrams) to match how you think about it.
Compoundsyringe

Which insulin syringe do you have?

Pick the insulin syringe you will draw with. All are U-100. On a 1 mL (100 unit) syringe each printed tick is 2 units, not 1. On 0.3 mL and 0.5 mL syringes each tick is 1 unit.
▶ How to read an insulin syringe
Compoundresult
Draw, U-100 units
10u
Draw volume
0.100mL
Concentration
2.5mg/mL
Aliquots / vial
20
Cost / aliquot
n/a
Draw to the 10 unit mark on your 0.5 mL syringe. Verify the figures independently before laboratory use.
▶ Watch the full reconstitution walkthrough
Add vial cost for cost per aliquot
Get the free Reconstitution Reference Card
22 compounds, BAC-water ratios, syringe units, and storage windows — one printable PDF.
Or just download the PDF ↓

Reference figures. Verify all calculations independently before laboratory use. 1 mL = 100 U-100 units. This tool does not recommend a dose, frequency, or protocol.

Reconstitution turns a freeze-dried (lyophilized) research peptide back into a liquid you can measure and draw with a syringe. The process is nearly identical across every compound: add a measured volume of bacteriostatic water, let it dissolve, and the math tells you the concentration and the exact draw for any research quantity.

What you need

  • The lyophilized peptide vial, at room temperature
  • Bacteriostatic water — sterile water with 0.9% benzyl alcohol as a preservative
  • Alcohol swabs
  • A syringe to draw the bacteriostatic water (commonly 3 mL)
  • A U-100 insulin syringe to draw your research quantity (0.3 mL, 0.5 mL, or 1.0 mL)

Step by step

  1. Warm to room temperature. Let the lyophilized peptide vial and the bacteriostatic water reach room temperature before mixing. Cold water onto a cold cake of powder dissolves unevenly and is more likely to foam.
  2. Swab both vial tops. Wipe the rubber stopper of the peptide vial and the bacteriostatic water vial with an alcohol swab and let them air dry.
  3. Draw the bacteriostatic water. Use a draw syringe to pull your chosen volume. See the bacteriostatic water guide for how to choose that volume.
  4. Inject it down the inside wall of the peptide vial. Angle the needle so the water runs down the glass onto the powder rather than hitting it directly — this reduces foaming.
  5. Let it dissolve on its own. Swirl gently if needed. Do not shake — shaking introduces air and mechanical stress that can degrade the peptide. Most peptides fully clear within a minute or two.
  6. Label the vial. Write the date and the resulting concentration (mg/mL) on the vial so you never have to guess later.
  7. Store it. Refrigerate the reconstituted vial at 2–8°C, out of direct light, and avoid repeated freeze-thaw cycles.

The math behind the draw

Every figure on this site comes from three formulas:

StepFormula
Concentrationvial mass (mg) ÷ BAC water (mL) = mg/mL
Draw volumeresearch quantity ÷ concentration (matching units) = mL
Syringe unitsdraw volume (mL) × 100 = U-100 units

Worked example: a 5 mg vial reconstituted in 2 mL of bacteriostatic water is 2.5 mg/mL (2,500 mcg/mL). A 250 mcg research quantity is 250 ÷ 2,500 = 0.10 mL, and 0.10 mL × 100 = 10 units on a U-100 syringe. Use the calculator above to run your own numbers instantly, with a live syringe visualizer.

Reading a U-100 insulin syringe

All three common insulin syringes are U-100, meaning 1 mL always equals 100 units — but the tick marks printed on the barrel are not all the same resolution. A 0.3 mL (30-unit) and a 0.5 mL (50-unit) syringe print 1 unit per tick. A 1.0 mL (100-unit) syringe prints 2 units per tick — so counting 10 ticks is actually 20 units, the single most common reconstitution mistake. Always read against the front edge of the plunger seal, not the back.

Storage after reconstitution

  • Refrigerate the reconstituted solution at 2–8°C.
  • Keep it out of direct light — some compounds (copper peptides like GHK-Cu, for example) are more light-sensitive than others.
  • Avoid repeated freeze-thaw cycles, which can degrade the peptide.
  • Draw with a fresh, sterile syringe every time to keep a multi-use vial sterile.
  • Discard the vial if the solution turns cloudy or shows particulates — that is not normal for a correctly reconstituted peptide.

Common mistakes

  • Shaking the vial. Shaking foams the solution and can degrade the peptide; swirl gently instead.
  • Misreading a 1 mL syringe. Each tick is 2 units, not 1 — see above.
  • Guessing the concentration instead of calculating it. The same vial can be 10 mg/mL or 2 mg/mL depending only on how much water you add — there is no universal "correct" ratio, only the one the math gives for your chosen volume.
  • Not labeling the vial. A reconstituted vial with no label and no date is a vial you can no longer trust.
  • Using plain sterile water for a multi-use vial. Bacteriostatic water's benzyl alcohol preservative is what makes repeated draws from the same vial reasonable; sterile water has none.
FAQ

Common questions, answered.

How long does bacteriostatic water last once it has reconstituted a peptide?

A commonly cited reference window is about 28 days for a refrigerated, punctured multi-dose vial, but this varies by product. See the bacteriostatic water guide for the full explanation, and always check your own vial’s documentation.

Can you use sterile water instead of bacteriostatic water?

Sterile water has no preservative, so once its vial is punctured it is intended for a single draw. Bacteriostatic water contains 0.9% benzyl alcohol, which is what lets the same multi-dose vial be drawn from repeatedly over its in-use window.

Do you need to refrigerate a peptide vial before reconstituting it?

Store the unopened lyophilized powder vial per its label (commonly refrigerated or frozen) until you are ready to use it. Let both it and the bacteriostatic water reach room temperature just before mixing — this helps the powder dissolve evenly.

Why shouldn’t you shake a peptide vial?

Shaking introduces air and mechanical stress that can foam the solution and degrade the peptide’s structure. Swirling gently, or simply letting it sit, dissolves the powder without that stress.

What if the peptide doesn’t fully dissolve?

Let it sit a little longer and swirl gently — most peptides fully clear within a couple of minutes. If it still will not dissolve, double-check the water volume and that the vial hasn’t expired. Do not use a solution that stays cloudy or shows visible particulates.

Is this a dosing calculator?

No. This is a reconstitution and concentration guide and calculator for in-vitro laboratory research. It does not provide medical advice, is not intended for human use, and does not establish a dosing recommendation.

Calculators

Every compound.

How these figures are verified. The formulas used here are standard and independently checkable: concentration = vial mass (mg) ÷ bacteriostatic water (mL); draw volume = research quantity ÷ concentration; U-100 units = draw volume (mL) × 100. Every result updates live and can be reproduced by hand or against published reconstitution references from R&D Systems and Tocris. This page covers reconstitution technique and handling only; it does not recommend a dose, frequency, or protocol. Reconstitute Editorial · Methodology · Last reviewed 2026-10-15
Sourcing

Reference materials you can verify.

Look for an independent Certificate of Analysis on every lot, third party testing, and lot traceability. Verify the source the way you verify the numbers here.

See COA verified materials